The White and Blue wires at the fan are connected to the White wire at the Puck. Any suggestions as to how to fix this? At the circuit breaker, fuse box, or wall light switch, turn the power off for the fan … My new ceiling fan is a 3-speed Kichler with an LED light and it says that it must use the remote system in order to operate. And yes. The right side of the box will be about 5" from the stud. I know position 2-white and position 7-black are the feed wires from the ceiling. On the puck side connector; Neutral- Tie white, blue and grey together. thanks saved me from buying yet another fan, seems like all my fans fail in the wireless control dept. (1 thin white and 2 thick white wires). ( Log Out /  Suddenly, the fan/light stopped working. My problem is the fan will only run in the highest three settings out of seven. All information is provided "AS IS." I chose the 5.5uF for low, but it still moves a lot of air directly above my couch. Gray Followed your diagram and done in minutes. I know this sounds stupid, especially with all the directions above. As far as i can tell, there should be no crossed (shorting) wires as I have it. The fan has power. Universal 3 speed ceiling fan remote (2 pages) Summary of Contents for Hunter 99119 Page 1 Spread the wires apart, with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box. The Light Limiter or No Bypass module, used on a ceiling fan, controls the wattage to the light kit. The first one I did, I did use a 3 speed (off/H/M/L) solid state switch that did adjust the speeds accordingly, but the rest are just a single pole paddle switch. They start up fine and run on High speed just fine. It says it’s in your trash and would like to look at it. Change ), You are commenting using your Google account. No problem! Joe<. If I plug in the working receiver from my other Altura fan, it has no problem going to full speed, but with the bypass version it only goes to medium. Operating a Hunter ceiling fan without the remote requires working with the electrical wiring within the fan's canopy to remove the wireless receiver. (link, http://www.homedepot.com/p/Home-Decorators-Collection-Altura-68-in-Oil-Rubbed-Bronze-Ceiling-Fan-26668/204729641, Click to share on Twitter (Opens in new window), Click to share on Facebook (Opens in new window), How to Bypass a Ceiling Fan Remote Control, https://drive.google.com/open?id=0B0-UArRIK29jaGtJYl92SjEyeDg, https://drive.google.com/open?id=0BxwSF-WSLkpTd3J1TzFHaFZ4LWs, http://chipwyly.com/fan_fix/PH20_Fan_ReWire_1. I hate to spend more on parts if the fan’s no good. It’s about 4 years old but it is rarely used. $47.99 + shipping . Which controls can I use with Casablanca pull chain fan? Electronic Equipment and Computers, Lighting, Light Fixtures, Ceiling and Exhaust Fans. Not sure if the clips just don't have the tension to hold the light anymore and if so what to do about that. With above conversion will fan now get full functions off a wall control switch? Email. I don’t like the remote control and only want on/off and speed control from the wall. **note: in the above photograph, the red wire leading to the puck is a splice wire I had lying around, I did not have a scrap of gray wire. 3 Speed Fan Switch Zing Ear ZE-268S6, Ceiling Fan Pulls 4 Wire Ceiling Fan Switch Compatible with Hunter Ceiling Fan, Appliances (Bronze Pull Chain) 4.2 out of 5 stars 27. Hunter Remote Control Transmitter Part Number: K047402000. One switch is for the light, the other may be a fan speed control dimmer — after having lived with it for a few months, I’m considering removing my dimmer and turning it to a simple on/off. 1. There is a remote inside the inner working of the fan, which responds to a remote control. Tie thin White to the other side of that cap. Just bite the bullet and buy a new receiver. Fingers crossed…. It's wired from the wall 12/3 to the fan. Hunter offers ceiling fan remote control options that make your fans both easier to operate and more energy-efficient. If you’re doing this to automate your house via your phone or via Alexa, get a remote repeater made by Bond. Repairing a Hunter Fan Remote Control: This is a Hunter UC7848. UNIVERSAL FAN AND LIGHT REMOTE CONTROL 27184 remote control pdf manual download. I had a couple questions, and judging by the lack of help I was able to find online, I thought I would put the information out there. I capped it and didn’t connect to anything. We loved the attractive, large inexpensive fan in family room. Which is contradicting the information on this forum. I called Hunter to ask for yet another remote receiver. https://drive.google.com/open?id=0BxwSF-WSLkpTd3J1TzFHaFZ4LWs, Thank you Wes Lovold for posting your diagram. However, what did you do with the blue wire on the puck? Am I missing anything or incorrect? There are remotes designed to go into a wall junction box as well as ones that have a small bracket for attaching to the wall. Indoor Matte Black Ceiling Fan with Remote Control and one bullet point about the Altura DC is that it has a “Powerful and quiet energy saving DC motor“ Fan side A 7-pin female female clip then distributes 7 wires to the fan motor and all wires are the same thickness. Can you post a better pic of the wiring? 4) for white ( for light ) wires, leave as is and connect to light kit white wire. Blue the outlet box and the ungrounded wires on the other side of the outlet box. It can be accomplished by removing the remote receiver and reconnecting the wires to the appropriate colored wires in the ceiling that run to the desired switch. If you really want the reverse function, best solution would be to install a small toggle on the fan itself (somewhere that won’t interfere with the blades). Of course I finished it off with the proper connectors and insulation for the final installs… We have over twenty of these Altura’s installed at our home and commercially. My wife bought 2 Hunter fans that came with fan/light remotes. thanks for your help. How Do I Pair My Ceiling Fan Remote? One of the switches within the working of the fan is connected to a remote, which can be controlled – as you may guess – remotely. FREE Shipping on orders over $25 shipped by Amazon. The fan is one hundred % controlled through a hand-held remote and the remote receiver; there is no wall switch. Just take it out and hook the wires directly. b. Connect other side of pull chain switch to black/thin white/brown combo. I held off for months because I thought I would have to remove the fan from the ceiling. I ran into this problem a few days ago with a Hunter remote unit and didn't really find an answer anywhere by googling. I’m having a little trouble following the directions from this post. I have included the drawing I made just so I could get it clear in my small noggin’ how it should go together, as well as a photo of the almost finished item. Reverse will NOT work with this configuration. Bank Robber Hyperbolist. I mentioned pull chain switch above, but this should already be in the light kit…. My 68″ Altuta definitely uses a standard a 120vac PSC or permanent split capacitor motor. Not sure if I'm missing something. The fan has four wires: Black. This includes Hampton Bay, Hunter and more. Turn of your fan using its dedicated remote control; Wait for 30 seconds before turning the fan on again. View and Download Hunter UNIVERSAL FAN AND LIGHT REMOTE CONTROL 27184 owners and installation manual online. I have two white wires on the puck, which do i use? Your diagram made it very easy to bypass the “puck” (remote receiver.). Here are pics of the light itself and the housing brackets. The puck simply uses remote controlled relays in place of the usual switches. Modify electronic devices at your own risk (and at risk of voiding the warranty), The majority of this came from a forum on AskMeHelpDesk.com, However, if you purchased an Altura Oil Rubbed Bronze fan (from the Home Decorators Collection) at Home Depot. [ATTACH]77134[/ATTACH] It has a remote and also pull chains. Every time I turn off the wall switch the lights would flicker but the fan won't operate. I read postings about bypassing the remote to isolate the problem, but can't find the actual steps to bypass the remote and test the fan … 1) I assume I cut the black, brown, and thin white wires and tie together on the fan side with a wire nut. Same guts, same wiring, but the colors in your harness don’t match up. Looking for some advice on bypassing the remote with adding a reversal switch. 99. Cheers. there is not a light kit nor will we run the fan in reverse. Wiring the fans through the switches isn't a problem and that's how I have them now. It’s plug and play, I just set it to high blowing downward and everything works as it should. Adding the Hunter remote receiver is … The name of the fan is the Home Decorators Collection Altura DC 68 in. These directions worked perfect for me. Brown But when I connect the Black, thin white, and blue together and the white and brown together, my breaker trips immediately. A remote-controlled ceiling fan bypasses one of the wall switches and allows for remote access to the ceiling fan's workings. Does it have a remote control? To Re-set: 1. It is very frustrating that the Fan On button wo… (link http://www.homedepot.com/p/Home-Decorators-Collection-Altura-68-in-Oil-Rubbed-Bronze-Ceiling-Fan-26668/204729641). White. I have it and love it. He said ceiling fan remotes are have problems. (diagram for fan pg 8) It is recommending being wire to the Black & White from the fan box and ignoring the red. 1. The remote control on my Hunter ceiling fan operates the fan.? Dissemble the puck and salvage the 3 big yellow capacitors. Awesome, thanks everyone. Black, Blue and white disconnected ( I assume for a light kit add on), Connect Thin White, Black and Brown wires from fan side to puck side (2 blacks on puck side: do i put both in this connection? Hunter Ceiling Fans with Apple HomeKit. Wasn’t looking forward to spending half the fan price for new remote receiver module. 2) Leave the thick white and gray wires intact and will connect to the puck. Wireless Timing Remote Control Receiver Universal Ceiling Fan Lamp Light Kit. Hi, answers in order 1) no remote control 2) yes, two pull chains. The fan is only about 6 months old. 3. I am using a dpdt toggle switch to connect the wires in down- off – up flow positions. If your remote controller has quit working or is a pain to use just bypass it and use a wall speed regulator.SOLVED: Hunter fan 02 bad remote can you hard wire - FixyaHunter fan remote bypass - schematron.org Community Forums Fill in your details below or click an icon to log in: You are commenting using your WordPress.com account. Can I use controls with an existing wall switch? Not the “for lighting” wire, but the dark blue? I approved your comment, but the diagram you mention came from a different user. https://www.replacementremotes.com/hampton-bay/buy-ceiling-fan-receiver-reverse-module-uc7067revb. If you have the add-on lighting kit, you will want to splice the White wire for the light to the White wire on the puck.